Student Physiograph

STUDENT PHYSIOGRAPH: An equipment from Bio Devices come to you with the backing of battery of the experienced, dedicated and devoted people, to ensure that it remains functional, hassle-free and an asset for you, for life. With the changing times and technology, system upgradation is a must in order to be with the Physiograph. Thereby, ensuring that with Student Physiograph, you always stay ahead.

Ease of Operation of STUDENT PHYSIOGRAPH:
Even a beginner can easily understand and operate the STUDENT PHYSIOGRAPH with just simple explanation. Controls are kept to be bare minimum, without sacrificing any function or sensitivity. Sensitivity has not been sacrificed in designing the STUDENT PHYSIOGRAPH. Sensitivities as high as 5 micro volts per mm are obtainable. Ruggedness is reliability, so essential for an instrument or system which would be used by different batches of students. Versatility through the use of couplers for recording of various parameters.

Concept of group experimentation with STUDENT PHYSIOGRAPH:
Group experimentation concept which permits more then one STUDENT PHYSIOGRAPH to be used independently or interconnected to each other for the same experiments set-up, or interchanged with each other to record from different experiment set-ups in the laboratory. The STUDENT PHYSIOGRAPH: is complete system design with couplers, matching Transducers & Pick-ups, and matching Electronics Stimulators with facility of synchronized event maker time maker.

Standard Transducer for STUDENT PHYSIOGRAPH:

1. Pressure Transducer

2. Respiration belt Transducer

3. Force Transducer

4. Volume Transducer

5. Pulse Transducer

6. Respiration Transducer

7. Temperature Transducer

8. Isotonic Transducer

9. 3 PIN Junction Box

10. 5 PIN Junction Box

Standard Accessories with STUDENT PHYSIOGRAPH:

· Earth Lead

· Ink Bottle

· EP to EP lead

· Fuse, capacity, steel wire & Motor belt

· Suitcase as a container

· Instruction manual

· Perspex pen Cover

· Rexine Cover

· Chart paper Z Fold ( 250 fold ) Single channel

Or

Chart paper Z Fold ( 250 fold ) Two channel

Or

Chart paper Z Fold ( 250 fold ) Three channel

Technical Specification of STUDENT PHYSIOGRAPH **:

No of Channel           :        1 (1+1)                   2(2+1)                     3(3+1)

Machine Dimension  :         386*201*168           436*336*168           436*336*168

Couplers Size           :        65*152 mm              65*152 mm              50*152 mm

Channel Width          :        70 mm                    70 mm each             70 mm each

Recording Paper       :        80mm                     150mm                    160mm

Time marker             :         Governed through Physiograph stimulator marking at 0.5, 1, 2, 3, 5 ,7, 10, 20, 30,

50,100 Per Sec Interval

Chart Speed            :        The 9 speed chat drive has 3 range of 1:10:100 selected by a range selector knob, and Electronic Stepper Control through Push Buttons to give 3 speed variations of 1:2:4 between each range giving a total of 9 speeds. Speed selection is both easy and instantaneous.

A       100              50                25

10                5                  2.5

1                  0.5               0.25 mm / Sec

B        50                25                12.5

5                  2.5               1.2

0.5               0.25             0.12 mm / Sec

LIST OF EXPERIMENTS WITH STUDENT PHYSIOGRAPH :

· NEROMUSCULAR PHYSIOLOGY

1.       Muscle Twist; various Experiments

2.      After load and free load contractions

3.      Strength of stimulus

4.      Summation of Stimuli.

5.      Tetanus

6.      Fatigue

7.      Isometric contraction, Length –Tension relationship

8.      Conduction velocity of nerve impulse

9.      Action potentials.

CARDO-VASCULAR PHYSIOLOGY:

1.      Arterial and Venous Pulse

2.      Blood pressure in Dog / Rabbit

3.      Effect of Drugs and automatic stimulation on B.P

4.      Plethysmography; Simple and Venous occlusion; Reactive Hyperaemia.

5.      E.C.G Clinical

6.      Electrical and Mechanical activity of frog heart.

7.      Effect of Temperature; Vagal Stimulation and drugs on heart;stannous Ligatures; Idioventricular rhythm.

8.      Perfusion of isolated frog heart; Effect of Vagal Stimulation and Drugs.

EXPERIMENTS ON RESPIRATORY SYSTEM:

1.      RESPIRATORY movements.

2.      Lung Volumes, Tidal Volume, IRV, ERV, VC, IC Etc.

3.      B.M.R

4.      Stethography

5.      Respiration of Dog / rabbit; Effect of Electrical Stimulation; Effect of

drugs etc.

HUMAN EXPERIEMENTS:

1.      ECG Clinical

2.      E.M.G

3.      E.E.G

4.      Nystagmus; Eye Movements.

5.      Finger Movements.

OTHER EXPERIEMENTS:

1.      Isolated Uterus; Effect of Drugs.

2.      Isolated intestine; Effect of Drugs.

3.      Rat diaphragm Prep; Effect of Drugs of Transmission at nerve Muscle synapse.

4.      Sciatic. Gastrocnemius prep; Study as in 3 above.

5.      Perfused mammalian heart; langedroff method; Effect of Drugs.

6.      Temperature; surface and rectal.

** Since R&D is a continuous process features and specification are

subject to change without notice

Download Pdf

  • PHYSIOGRAPH.pdf (Downloaded 360 times)